-- DLINK Private MIB -- DLINK agents also support the following Public MIBs: -- MIB-II ( RFC1213 ) -- dlkEnterpriseAP-dlk80211bPlus MODULE DLINK-WLAN-MIB DEFINITIONS ::= BEGIN IMPORTS mgmt, enterprises, IpAddress FROM RFC1155-SMI OBJECT-TYPE, Integer32, Counter32 FROM SNMPv2-SMI -- OBJECT-TYPE, Integer32, Counter32 FROM RFC-1212 DisplayString, MacAddress, RowStatus, TruthValue FROM SNMPv2-TC ifIndex FROM RFC1213-MIB ; --mgmt OBJECT IDENTIFIER ::= { iso org(3) dod(6) internet(1) mgmt(2) } --mib OBJECT IDENTIFIER ::= { mgmt 1 } --directory OBJECT IDENTIFIER ::= { internet 1 } --experimental OBJECT IDENTIFIER ::= { internet 3 } --private OBJECT IDENTIFIER ::= { internet 4 } --enterprises OBJECT IDENTIFIER ::= { private 1 } dlink OBJECT IDENTIFIER ::= { enterprises 171 } --should be implemented as module --dlkEnterpriseAP OBJECT IDENTIFIER ::= { dlink 1 } --dlkWLANRouter OBJECT IDENTIFIER ::= { dlink 2 } --dlkRouter OBJECT IDENTIFIER ::= { dlink 3 } -- ********************************************************************** -- * MODULE IDENTITY -- ********************************************************************** dlkEnterpriseAP MODULE-IDENTITY LAST-UPDATED "200208160000Z" ORGANIZATION "D-Link, Inc." CONTACT-INFO "Postal: D-Link, Inc. 2F, No.233-2, Pao-Chiao Road, Hsin-Tien, Taipei, Taiwan, R.O.C. Tel: +886-2-29161600 Fax: +886-2-29146299" DESCRIPTION "The MIB module for D-Link 802.11 series product. This module derived from IEEE ieee802dot11" ::= { dlink 1 } -- ********************************************************************** -- * end of MODULE IDENTITY -- ********************************************************************** -- dlkEnterpriseAP OBJECT IDs Groups dlkEnterpriseAPsys OBJECT IDENTIFIER ::= { dlkEnterpriseAP 1 } dlkEnterpriseAPlan OBJECT IDENTIFIER ::= { dlkEnterpriseAP 2 } dlk80211bPlusDot11 OBJECT IDENTIFIER ::= { dlkEnterpriseAP 3 } dlkEnterpriseAPTrap OBJECT IDENTIFIER ::= { dlkEnterpriseAP 4 } -- ********************************************************************** -- * Major sections -- ********************************************************************** -- ********************************************************************** -- * dlkEnterpriseAPsys sections -- ********************************************************************** enterpriseAPSysConfigSave OBJECT-TYPE SYNTAX INTEGER { write(1) } MAX-ACCESS read-write STATUS current DESCRIPTION "User must manually SET this OID in order to save the change(s) made through SNMP to main configuration." ::= { dlkEnterpriseAPsys 1 } enterpriseAPSysReboot OBJECT-TYPE SYNTAX INTEGER { reboot(1) } MAX-ACCESS read-write STATUS current DESCRIPTION "This attribute is to reboot the enterprise AP system. Doesn't save the changes that had been made." ::= { dlkEnterpriseAPsys 2 } enterpriseAPSysConfigApply OBJECT-TYPE SYNTAX INTEGER { saveAndReboot(1) } MAX-ACCESS read-write STATUS current DESCRIPTION "This attribute is equivalent of setting enterpriseAPSysConfigSave then enterpriseAPSysConfigApply." ::= { dlkEnterpriseAPsys 3 } -- ********************************************************************** -- * end of dlkEnterpriseAPsys sections -- ********************************************************************** -- Station ManagemenT (SMT) Attributes -- DEFINED AS "The SMT object class provides the necessary support at the -- station to manage the processes in the station such that the -- station may work cooperatively as a part of an IEEE 802.11 network."; dot11smt OBJECT IDENTIFIER ::= { dlk80211bPlusDot11 1 } dot11StationConfigEntry OBJECT IDENTIFIER ::= { dot11smt 1 } dot11APModeConfigEntry OBJECT IDENTIFIER ::= { dot11smt 2 } dot11PrivacyEntry OBJECT IDENTIFIER ::= { dot11smt 3 } -- MAC Attributes -- DEFINED AS "The MAC object class provides the necessary support -- for the access control, generation, and verification of frame check -- sequences, and proper delivery of valid data to upper layers."; dot11mac OBJECT IDENTIFIER ::= {dlk80211bPlusDot11 2} dot11OperationEntry OBJECT IDENTIFIER ::= {dot11mac 1} dot11CountersEntry OBJECT IDENTIFIER ::= {dot11mac 2} -- dot11GroupAddressesTable ::= {dot11mac 3} -- Resource Type ID dot11res OBJECT IDENTIFIER ::= {dlk80211bPlusDot11 3} dot11resAttribute OBJECT IDENTIFIER ::= {dot11res 1 } -- PHY Attributes -- DEFINED AS "The PHY object class provides the necessary support -- for required PHY operational information that may vary from PHY -- to PHY and from STA to STA to be communicated to upper layers." dot11phy OBJECT IDENTIFIER ::= {dlk80211bPlusDot11 4} dot11PhyOperationEntry OBJECT IDENTIFIER ::= {dot11phy 1} dot11PhyAntennaEntry OBJECT IDENTIFIER ::= {dot11phy 2} dot11PhyTxPowerEntry OBJECT IDENTIFIER ::= {dot11phy 3} dot11PhyDSSSEntry OBJECT IDENTIFIER ::= {dot11phy 4} -- **************************************************************************************** -- dlkEnterpriseAPsys - system/platform MIB elements -- **************************************************************************************** -- **************************************************************************************** -- dlkEnterpriseAPlan - Ethernet Standard MIB elements -- **************************************************************************************** -- ********************************************************************** -- * Textual conventions from 802 definitions -- ********************************************************************** -- ********************************************************************** -- * SMT Station Config Table -- ********************************************************************** dot11StationID OBJECT-TYPE SYNTAX MacAddress MAX-ACCESS read-only STATUS deprecated DESCRIPTION "The purpose of dot11StationID is to allow a manager to identify a station for its own purposes. This attribute provides for that eventuality while keeping the true MAC address independent. Its syntax is MAC address and default value is the station's assigned, unique MAC address." ::= { dot11StationConfigEntry 1 } dot11PrivacyOptionImplemented OBJECT-TYPE SYNTAX TruthValue MAX-ACCESS read-only STATUS current DESCRIPTION "This attribute, when true, shall indicate that the IEEE 802.11 WEP option is implemented. The default value of this attribute shall be false." ::= { dot11StationConfigEntry 2 } dot11PowerManagementMode OBJECT-TYPE SYNTAX INTEGER { active(1), powersave(2) } MAX-ACCESS read-only STATUS current DESCRIPTION "This attribute shall specify the power management mode of the STA. When set to active, it shall indicate that the station is not in power-save mode. When set to powersave, it shall indicate that the station is in power-save mode. The power management mode is transmitted in all frames according to the rules in 7.1.3.1.7." ::= { dot11StationConfigEntry 3 } dot11DesiredSSID OBJECT-TYPE SYNTAX OCTET STRING (SIZE(0..32)) MAX-ACCESS read-write STATUS current DESCRIPTION "This attribute reflects the Service Set ID used in the DesiredSSID parameter of the most recent MLME_Scan.request. This value may be modified by an external management entity and used by the local SME to make decisions about the Scanning process." ::= { dot11StationConfigEntry 4 } dot11DesiredBSSType OBJECT-TYPE SYNTAX INTEGER { infrastructure(1), independent(2), any(3) } MAX-ACCESS read-only STATUS current DESCRIPTION "This attribute shall specify the type of BSS the station shall use when scanning for a BSS with which to synchronize. This value is used to filter Probe Response frames and Beacons. When set to infrastructure, the station shall only synchronize with a BSS whose Capability Information field has the ESS subfield set to 1. When set to independent, the station shall only synchronize with a BSS whose Capability Information field has the IBSS subfield set to 1. When set to any, the station may synchronize to either type of BSS." ::= { dot11StationConfigEntry 5 } dot11OperationalRateSet OBJECT-TYPE SYNTAX OCTET STRING (SIZE(1..126)) MAX-ACCESS read-write STATUS current DESCRIPTION "This attribute shall specify the set of data rates at which the station may transmit data. Each octet contains a value representing a rate. Each rate shall be within the range from 2 to 127, corresponding to data rates in increments of 500 kb/s from 1 Mb/s to 63.5 Mb/s, and shall be supported (as indicated in the supported rates table) for receiving data. This value is reported in transmitted Beacon, Probe Request, Probe Response, Association Request, Association Response, Reassociation Request, and Reassociation Response frames, and is used to determine whether a BSS with which the station desires to synchronize is suitable. It is also used when starting a BSS, as specified in 10.3. This atribute also indicate the Basic Rate of the AP, rate that is used as transmit rate of 802.11 management and control packet. If 22Mbps is as basic rate, the bit 7(MSB) should be set(i.e. 0xAC, instead of 0x2C). Valid basic rate are (2-1)Mbps, (11-5.5-2-1)Mbps, (22-11-5.5-2-1)Mbps. example: (2-1)Mbps : 0x2C160B8482 (11-5.5-2-1)Mbps : 0x2C968B8482 (22-11-5.5-2-1)Mbps : 0xAC968B8482" ::= { dot11StationConfigEntry 6 } dot11BeaconPeriod OBJECT-TYPE SYNTAX INTEGER (1..1000) MAX-ACCESS read-write STATUS current DESCRIPTION "This attribute shall specify the number of TU that a station shall use for scheduling Beacon transmissions. This value is transmitted in Beacon and Probe Response frames." ::= { dot11StationConfigEntry 7 } dot11DTIMPeriod OBJECT-TYPE SYNTAX INTEGER(1..255) MAX-ACCESS read-write STATUS current DESCRIPTION "This attribute shall specify the number of beacon intervals that shall elapse between transmission of Beacons frames containing a TIM element whose DTIM Count field is 0. This value is transmitted in the DTIM Period field of Beacon frames." ::= { dot11StationConfigEntry 8 } dot11DisassociateReason OBJECT-TYPE SYNTAX INTEGER(0..65535) MAX-ACCESS read-only STATUS current DESCRIPTION "This attribute holds the most recently transmitted Reason Code in a Disassociation frame. If no Disassociation frame has been transmitted, the value of this attribute shall be 0." REFERENCE "IEEE Std 802.11-1997, 7.3.1.7" ::= { dot11StationConfigEntry 9 } dot11DisassociateStation OBJECT-TYPE SYNTAX MacAddress MAX-ACCESS read-only STATUS current DESCRIPTION "This attribute holds the MAC address from the Address 1 field of the most recently transmitted Disassociation frame. If no Disassociation frame has been transmitted, the value of this attribute shall be 0." ::= { dot11StationConfigEntry 10 } dot11DeauthenticateReason OBJECT-TYPE SYNTAX INTEGER(0..65535) MAX-ACCESS read-only STATUS current DESCRIPTION "This attribute holds the most recently transmitted Reason Code in a Deauthentication frame. If no Deauthentication frame has been transmitted, the value of this attribute shall be 0." REFERENCE "IEEE Std 802.11-1997, 7.3.1.7" ::= { dot11StationConfigEntry 11 } dot11DeauthenticateStation OBJECT-TYPE SYNTAX MacAddress MAX-ACCESS read-only STATUS current DESCRIPTION "This attribute holds the MAC address from the Address 1 field of the most recently transmitted Deauthentication frame. If no Deauthentication frame has been transmitted, the value of this attribute shall be 0." ::= { dot11StationConfigEntry 12 } dot11AuthenticateFailStatus OBJECT-TYPE SYNTAX INTEGER(0..65535) MAX-ACCESS read-only STATUS current DESCRIPTION "This attribute holds the most recently transmitted Status Code in a failed Authentication frame. If no failed Authentication frame has been transmitted, the value of this attribute shall be 0." REFERENCE "IEEE Std 802.11-1997, 7.3.1.9" ::= { dot11StationConfigEntry 13 } -- ********************************************************************** -- * End of dot11StationConfig TABLE -- ********************************************************************** -- ********************************************************************** -- * dot11EnterpriseConfigEntry TABLE -- ********************************************************************** dot11AccessPointMode OBJECT-TYPE SYNTAX INTEGER { accessPoint (1), wirelessBridge (2), wirelessAPClient (3), wirelessMultiBridge (4), backupAccessPoint (5), repeater (6), groupAccessPoint (7) } MAX-ACCESS read-write STATUS current DESCRIPTION "This attribute shall be a set of all the access point mode supported by the AP. The following are the default values and the associated mode. Value = 1: Normal AP Value = 2: Wireless Bridge Value = 3: Wireless AP Client Value = 4: Wireless Multi Bridge Value = 5: Backup AP Value = 6: Repeater Value = 7: Group AP" ::= { dot11APModeConfigEntry 1 } dot11RemoteMACAddress OBJECT-TYPE SYNTAX MacAddress MAX-ACCESS read-write STATUS current DESCRIPTION "This Remote MAC Address used by these following AP mode: Wireless Bridge, Wireless AP Client, Backup AP, Repeater. Consequently, this attribute must be set if any above mentioned mode is desired." ::= { dot11APModeConfigEntry 2 } dot11BackupAPRemoteServerIPAddress OBJECT-TYPE SYNTAX IpAddress MAX-ACCESS read-write STATUS current DESCRIPTION "This attribute used to check the wired LAN connection (A.K.A. Link Integrity) when AP in Backup AP mode." ::= { dot11APModeConfigEntry 3 } dot11GroupAPID OBJECT-TYPE SYNTAX OCTET STRING (SIZE(0..32)) MAX-ACCESS read-write STATUS current DESCRIPTION "This attribute is to identify current Group ID of the AP." ::= { dot11APModeConfigEntry 4 } -- ********************************************************************** -- * End of dot11EnterpriseConfigEntry TABLE -- ********************************************************************** -- ********************************************************************** -- * dot11PrivacyTable TABLE -- ********************************************************************** dot11AuthenticationAlgorithm OBJECT-TYPE SYNTAX INTEGER { openSystem (1), sharedKey (2), both (3) } MAX-ACCESS read-only STATUS current DESCRIPTION "This attribute shall be the authentication algorithms currently used by the AP. The following are the default values and the associated algorithm. Value = 1: Open System Value = 2: Shared Key Value = 3: Both Open System and Shared Key" ::= { dot11PrivacyEntry 1 } dot11PrivacyInvoked OBJECT-TYPE SYNTAX TruthValue MAX-ACCESS read-write STATUS current DESCRIPTION "When this attribute is true, it shall indicate that the IEEE 802.11 WEP mechanism is used for transmitting frames of type Data. The default value of this attribute shall be false." ::= { dot11PrivacyEntry 2 } dot11WEPDefaultKeyID OBJECT-TYPE SYNTAX INTEGER (0..3) MAX-ACCESS read-write STATUS current DESCRIPTION "This attribute shall indicate the use of the first, second, third, or fourth element of the WEPDefaultKeys array when set to values of zero, one, two, or three. The default value of this attribute shall be 0." REFERENCE "IEEE Std 802.11-1997, 8.3.2" ::= { dot11PrivacyEntry 3 } dot11WEPKeyLength OBJECT-TYPE SYNTAX INTEGER { w-64Bit (1), w-128Bit (2), w-256Bit (3) } MAX-ACCESS read-write STATUS current DESCRIPTION "This attribute shall indicate the length of WEP encryption length used. Value 1: 64 bit that need 5 characters of WEP Default Key Value 2: 128 bit that need 13 characters of WEP Default Key Value 3: 256 bit that need 29 characters of WEP Default Key" ::= { dot11PrivacyEntry 4 } dot11WEPKeyMappingLength OBJECT-TYPE SYNTAX INTEGER (10..64) MAX-ACCESS read-only STATUS current DESCRIPTION "The maximum number of tuples that dot11WEPKeyMappings can hold." REFERENCE "IEEE Std 802.11-1997, 8.3.2" ::= { dot11PrivacyEntry 5 } dot11ExcludeUnencrypted OBJECT-TYPE SYNTAX TruthValue MAX-ACCESS read-only STATUS current DESCRIPTION "When this attribute is true, the STA shall not indicate at the MAC service interface received MSDUs that have the WEP subfield of the Frame Control field equal to zero. When this attribute is false, the STA may accept MSDUs that have the WEP subfield of the Frame Control field equal to zero. The default value of this attribute shall be false." ::= { dot11PrivacyEntry 6 } dot11WEPICVErrorCount OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "This counter shall increment when a frame is received with the WEP subfield of the Frame Control field set to one and the value of the ICV as received in the frame does not match the ICV value that is calculated for the contents of the received frame." ::= { dot11PrivacyEntry 7 } dot11WEPExcludedCount OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "This counter shall increment when a frame is received with the WEP subfield of the Frame Control field set to zero and the value of dot11ExcludeUnencrypted causes that frame to be discarded." ::= { dot11PrivacyEntry 8 } -- ********************************************************************** -- * End of dot11Privacy TABLE -- ********************************************************************** -- ********************************************************************** -- * MAC Attribute Templates -- ********************************************************************** -- ********************************************************************** -- * dot11OperationTable TABLE -- ********************************************************************** dot11MACAddress OBJECT-TYPE SYNTAX MacAddress MAX-ACCESS read-only STATUS current DESCRIPTION "Unique MAC Address assigned to the STA." ::= { dot11OperationEntry 1 } dot11RTSThreshold OBJECT-TYPE SYNTAX INTEGER (256..2432) MAX-ACCESS read-write STATUS current DESCRIPTION "This attribute shall indicate the number of octets in an MPDU, below which an RTS/CTS handshake shall not be performed. An RTS/CTS handshake shall be performed at the beginning of any frame exchange sequence where the MPDU is of type Data or Management, the MPDU has an individual address in the Address1 field, and the length of the MPDU is greater than this threshold. (For additional details, refer to Table 21 in 9.7.) Setting this attribute to be larger than the maximum MSDU size shall have the effect of turning off the RTS/CTS handshake for frames of Data or Management type transmitted by this STA. Setting this attribute to zero shall have the effect of turning on the RTS/CTS handshake for all frames of Data or Management type transmitted by this STA. The default value of this attribute shall be 2347." ::= { dot11OperationEntry 2 } dot11ShortRetryLimit OBJECT-TYPE SYNTAX INTEGER (1..255) MAX-ACCESS read-write STATUS current DESCRIPTION "This attribute shall indicate the maximum number of transmission attempts of a frame, the length of which is less than or equal to dot11RTSThreshold, that shall be made before a failure condition is indicated. The default value of this attribute shall be 7." ::= { dot11OperationEntry 3 } dot11LongRetryLimit OBJECT-TYPE SYNTAX INTEGER (1..255) MAX-ACCESS read-write STATUS current DESCRIPTION "This attribute shall indicate the maximum number of transmission attempts of a frame, the length of which is greater than dot11RTSThreshold, that shall be made before a failure condition is indicated. The default value of this attribute shall be 4." ::= { dot11OperationEntry 4 } dot11FragmentationThreshold OBJECT-TYPE SYNTAX INTEGER (256..2346) MAX-ACCESS read-write STATUS current DESCRIPTION "This attribute shall specify the current maximum size, in octets, of the MPDU that may be delivered to the PHY. An MSDU shall be broken into fragments if its size exceeds the value of this attribute after adding MAC headers and trailers. An MSDU or MMPDU shall be fragmented when the resulting frame has an individual address in the Address1 field, and the length of the frame is larger than this threshold. The default value for this attribute shall be the lesser of 2346 or the aMPDUMaxLength of the attached PHY and shall never exceed the lesser of 2346 or the aMPDUMaxLength of the attached PHY. The value of this attribute shall never be less than 256. " ::= { dot11OperationEntry 5 } dot11SSIDBroadcast OBJECT-TYPE SYNTAX TruthValue MAX-ACCESS read-write STATUS current DESCRIPTION "This attribute indicate whether SSID broadcast is enabled." ::= { dot11OperationEntry 6 } dot11PreambleType OBJECT-TYPE SYNTAX INTEGER { longPreamble (1), shortPreamble (2) } MAX-ACCESS read-write STATUS current DESCRIPTION "This attribute indicate what preamble type is used. The default value should be Long Preamble." ::= { dot11OperationEntry 7 } dot11MaxTransmitMSDULifetime OBJECT-TYPE SYNTAX INTEGER (1..65535) MAX-ACCESS read-write STATUS current DESCRIPTION "The MaxTransmitMSDULifetime shall be the elapsed time in TU, after the initial transmission of an MSDU, after which further attempts to transmit the MSDU shall be terminated. The default value of this attribute shall be 512." ::= { dot11OperationEntry 8 } dot11MaxReceiveLifetime OBJECT-TYPE SYNTAX INTEGER (1..65535) MAX-ACCESS read-write STATUS current DESCRIPTION "The MaxReceiveLifetime shall be the elapsed time in TU, after the initial reception of a fragmented MMPDU or MSDU, after which further attempts to reassemble the MMPDU or MSDU shall be terminated. The default value shall be 512." ::= { dot11OperationEntry 9 } dot11ManufacturerID OBJECT-TYPE SYNTAX DisplayString (SIZE(0..128)) MAX-ACCESS read-only STATUS current DESCRIPTION "The ManufacturerID shall include, at a minimum, the name of the manufacturer. It may include additional information at the manufacturer's discretion. The default value of this attribute shall be null." ::= { dot11OperationEntry 10 } dot11ProductID OBJECT-TYPE SYNTAX DisplayString (SIZE(0..128)) MAX-ACCESS read-only STATUS current DESCRIPTION "The ProductID shall include, at a minimum, an identifier that is unique to the manufacturer. It may include additional information at the manufacturer's discretion. The default value of this attribute shall be null." ::= { dot11OperationEntry 11 } -- ********************************************************************** -- * End of dot11OperationEntry TABLE -- ********************************************************************** -- ********************************************************************** -- * dot11Counters TABLE -- ********************************************************************** dot11TransmittedFragmentCount OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "This counter shall be incremented for an acknowledged MPDU with an individual address in the address 1 field or an MPDU with a multicast address in the address 1 field of type Data or Management." ::= { dot11CountersEntry 1 } dot11MulticastTransmittedFrameCount OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION " This counter shall increment only when the multicast bit is set in the destination MAC address of a successfully transmitted MSDU. When operating as a STA in an ESS, where these frames are directed to the AP, this implies having received an acknowledgment to all associated MPDUs. " ::= { dot11CountersEntry 2 } dot11FailedCount OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "This counter shall increment when an MSDU is not transmitted successfully due to the number of transmit attempts exceeding either the dot11ShortRetryLimit or dot11LongRetryLimit. " ::= { dot11CountersEntry 3 } dot11RetryCount OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "This counter shall increment when an MSDU is successfully transmitted after one or more retransmissions." ::= { dot11CountersEntry 4 } dot11MultipleRetryCount OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "This counter shall increment when an MSDU is successfully transmitted after more than one retransmission." ::= { dot11CountersEntry 5 } dot11FrameDuplicateCount OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "This counter shall increment when a frame is received that the Sequence Control field indicates is a duplicate." ::= { dot11CountersEntry 6 } dot11RTSSuccessCount OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "This counter shall increment when a CTS is received in response to an RTS." ::= { dot11CountersEntry 7 } dot11RTSFailureCount OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "This counter shall increment when a CTS is not received in response to an RTS." ::= { dot11CountersEntry 8 } dot11ACKFailureCount OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "This counter shall increment when an ACK is not received when expected." ::= { dot11CountersEntry 9 } dot11ReceivedFragmentCount OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "This counter shall be incremented for each successfully received MPDU of type Data or Management." ::= { dot11CountersEntry 10 } dot11MulticastReceivedFrameCount OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "This counter shall increment when a MSDU is received with the multicast bit set in the destination MAC address." ::= { dot11CountersEntry 11 } dot11FCSErrorCount OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "This counter shall increment when an FCS error is detected in a received MPDU." ::= { dot11CountersEntry 12 } dot11TransmittedFrameCount OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "This counter shall increment for each successfully transmitted MSDU." ::= { dot11CountersEntry 13 } dot11WEPUndecryptableCount OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "This counter shall increment when a frame is received with the WEP subfield of the Frame Control field set to one and the WEPOn value for the key mapped to the TA's MAC address indicates that the frame should not have been encrypted or that frame is discarded due to the receiving STA not implementing the privacy option." ::= { dot11CountersEntry 14 } -- ********************************************************************** -- * End of dot11CountersEntry TABLE -- ********************************************************************** -- ********************************************************************** -- * Resource Type Attribute Templates -- ********************************************************************** dot11ResourceTypeIDName OBJECT-TYPE SYNTAX DisplayString (SIZE(4)) MAX-ACCESS read-only STATUS current DESCRIPTION "Contains the name of the Resource Type ID managed object. The attribute is read-write and always contains the value RTID. This attribute value shall not be used as a naming attribute for any other managed object class." REFERENCE "IEEE Std 802.1F-1993, A.7" DEFVAL {"RTID"} ::= { dot11resAttribute 1 } -- ********************************************************************** -- * dot11ResourceInfo TABLE -- ********************************************************************** -- REFERENCE "IEEE Std 802.1F-1993, A.7" dot11ResourceInfoEntry OBJECT IDENTIFIER ::= { dot11resAttribute 2 } dot11manufacturerOUI OBJECT-TYPE SYNTAX OCTET STRING (SIZE(3)) MAX-ACCESS read-only STATUS current DESCRIPTION "Takes the value of an organizationally unique identifier. 0x00032F for D-Link, Inc." ::= { dot11ResourceInfoEntry 1 } dot11manufacturerName OBJECT-TYPE SYNTAX DisplayString (SIZE(0..128)) MAX-ACCESS read-only STATUS current DESCRIPTION "A printable string used to identify the manufacturer of the resource. Maximum string length is 128 octets. D-Link, Inc." ::= { dot11ResourceInfoEntry 2 } dot11manufacturerProductName OBJECT-TYPE SYNTAX DisplayString (SIZE(0..128)) MAX-ACCESS read-only STATUS current DESCRIPTION "A printable string used to identify the manufacturer's product name of the resource. Maximum string length is 128 octets." ::= { dot11ResourceInfoEntry 3 } dot11manufacturerProductVersion OBJECT-TYPE SYNTAX DisplayString (SIZE(0..128)) MAX-ACCESS read-only STATUS current DESCRIPTION "Printable string used to identify the manufacturer's product version of the resource. Maximum string length is 128 octets." ::= { dot11ResourceInfoEntry 4 } -- ********************************************************************** -- * End of dot11ResourceInfo TABLE -- ********************************************************************** -- ********************************************************************** -- * PHY Attribute Templates -- ********************************************************************** -- ********************************************************************** -- * dot11PhyOperation TABLE -- ********************************************************************** dot11PHYType OBJECT-TYPE SYNTAX INTEGER {fhss(1), dsss(2), irbaseband(3)} MAX-ACCESS read-only STATUS current DESCRIPTION "This is an 8-bit integer value that identifies the PHY type supported by the attached PLCP and PMD. Currently defined values and their corresponding PHY types are: FHSS 2.4 GHz = 01 , DSSS 2.4 GHz = 02, IR Baseband = 03" ::= { dot11PhyOperationEntry 1 } dot11CurrentRegDomain OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The current regulatory domain this instance of the PMD is supporting. This object corresponds to one of the RegDomains listed in dot11RegDomainsSupported." ::= { dot11PhyOperationEntry 2 } dot11TempType OBJECT-TYPE SYNTAX INTEGER {tempType1(1), tempType2(2) } MAX-ACCESS read-only STATUS current DESCRIPTION "There are different operating temperature requirements dependent on the anticipated environmental conditions. This attribute describes the current PHY's operating temperature range capability. Currently defined values and their corresponding temperature ranges are: Type 1 = X'01'-Commercial range of 0 to 40 degrees C, Type 2 = X'02'-Industrial range of -30 to 70 degrees C." ::= { dot11PhyOperationEntry 3 } dot11RegDomainsSupportValue OBJECT-TYPE SYNTAX INTEGER {fcc(16), doc(32), etsi(48), spain (49), france (50), mkk (64) } MAX-ACCESS read-only STATUS current DESCRIPTION "There are different operational requirements dependent on the regulatory domain. This attribute list describes the regulatory domains the PLCP and PMD support in this implementation. Currently de- fined values and their corresponding Regulatory Domains are: FCC (USA) = X'10', DOC (Canada) = X'20', ETSI (most of Europe) = X'30', Spain = X'31', France = X'32', MKK (Japan) = X'40' " ::= { dot11PhyOperationEntry 4 } dot11SupportedDataRatesTxValue OBJECT-TYPE SYNTAX Integer32 (2..127) MAX-ACCESS read-only STATUS current DESCRIPTION "The Transmit bit rates supported by the PLCP and PMD, represented by a count from X?2-X?f, corresponding to data rates in increments of 500Kb/s from 1 Mb/s to 63.5 Mb/s subject to limitations of each individual PHY." ::= { dot11PhyOperationEntry 5 } dot11SupportedDataRatesRxValue OBJECT-TYPE SYNTAX Integer32 (2..127) MAX-ACCESS read-only STATUS current DESCRIPTION "The receive bit rates supported by the PLCP and PMD, represented by a count from X?2-X?f, corresponding to data rates in increments of 500Kb/s from 1 Mb/s to 63.5 Mb/s." ::= { dot11PhyOperationEntry 6 } dot11CurrentTxRate OBJECT-TYPE SYNTAX INTEGER (2..127) MAX-ACCESS read-write STATUS current DESCRIPTION "The current tx operating rate. corresponding to data rates in increments of 500Kb/s from 1 Mb/s to 63.5 Mb/s." ::= { dot11PhyOperationEntry 7 } dot11ChannelAgilityPresent OBJECT-TYPE SYNTAX TruthValue MAX-ACCESS read-only STATUS current DESCRIPTION "This attribute indicates that the PHY is capable of channel agility." ::= { dot11PhyOperationEntry 8 } dot11ChannelAgilityEnabled OBJECT-TYPE SYNTAX TruthValue MAX-ACCESS read-only STATUS current DESCRIPTION "This attribute indicates that the PHY channel agility functionality is enabled." ::= { dot11PhyOperationEntry 9 } -- ********************************************************************** -- * End of dot11PhyOperation TABLE -- ********************************************************************** -- ********************************************************************** -- * dot11PhyAntenna TABLE -- ********************************************************************** dot11CurrentTxAntenna OBJECT-TYPE SYNTAX Integer32 (1..255) MAX-ACCESS read-only STATUS current DESCRIPTION "The current antenna being used to transmit. This value is one of the values appearing in dot11SupportedTxAntenna. This may be used by a management agent to control which antenna is used for transmission. " ::= { dot11PhyAntennaEntry 1 } dot11DiversitySupport OBJECT-TYPE SYNTAX INTEGER {fixedlist(1), notsupported(2), dynamic(3)} MAX-ACCESS read-only STATUS current DESCRIPTION "This implementation's support for diversity, encoded as: X'01'-diversity is available and is performed over the fixed list of antennas defined in dot11DiversitySelectionRx. X'02'-diversity is not supported. X'03'-diversity is supported and control of diversity is also available, in which case the attribute dot11DiversitySelectionRx can be dynamically modified by the LME." ::= { dot11PhyAntennaEntry 2 } dot11CurrentRxAntenna OBJECT-TYPE SYNTAX Integer32 (1..255) MAX-ACCESS read-only STATUS current DESCRIPTION "The current antenna being used to receive, if the dot11 DiversitySupport indicates that diversity is not supported. The selected antenna shall be one of the antennae marked for receive in the dot11AntennasListTable. " ::= { dot11PhyAntennaEntry 3 } -- ********************************************************************** -- * End of dot11PhyAntenna TABLE -- ********************************************************************** -- ********************************************************************** -- * dot11PhyTxPower TABLE -- ********************************************************************** dot11NumberSupportedPowerLevels OBJECT-TYPE SYNTAX INTEGER (1..8) MAX-ACCESS read-only STATUS current DESCRIPTION "The number of power levels supported by the PMD. This attribute can have a value of 1 to 8." ::= { dot11PhyTxPowerEntry 1 } dot11TxPowerLevel1 OBJECT-TYPE SYNTAX INTEGER (0..10000) MAX-ACCESS read-only STATUS current DESCRIPTION "The transmit output power for LEVEL1 in mW. This is also the default power level." ::= { dot11PhyTxPowerEntry 2 } dot11TxPowerLevel2 OBJECT-TYPE SYNTAX INTEGER (0..10000) MAX-ACCESS read-only STATUS current DESCRIPTION "The transmit output power for LEVEL2 in mW." ::= { dot11PhyTxPowerEntry 3 } dot11TxPowerLevel3 OBJECT-TYPE SYNTAX INTEGER (0..10000) MAX-ACCESS read-only STATUS current DESCRIPTION "The transmit output power for LEVEL3 in mW." ::= { dot11PhyTxPowerEntry 4 } dot11TxPowerLevel4 OBJECT-TYPE SYNTAX INTEGER (0..10000) MAX-ACCESS read-only STATUS current DESCRIPTION "The transmit output power for LEVEL4 in mW." ::= { dot11PhyTxPowerEntry 5 } dot11TxPowerLevel5 OBJECT-TYPE SYNTAX INTEGER (0..10000) MAX-ACCESS read-only STATUS current DESCRIPTION "The transmit output power for LEVEL5 in mW." ::= { dot11PhyTxPowerEntry 6 } dot11TxPowerLevel6 OBJECT-TYPE SYNTAX INTEGER (0..10000) MAX-ACCESS read-only STATUS current DESCRIPTION "The transmit output power for LEVEL6 in mW." ::= { dot11PhyTxPowerEntry 7 } dot11TxPowerLevel7 OBJECT-TYPE SYNTAX INTEGER (0..10000) MAX-ACCESS read-only STATUS current DESCRIPTION "The transmit output power for LEVEL7 in mW." ::= { dot11PhyTxPowerEntry 8 } dot11TxPowerLevel8 OBJECT-TYPE SYNTAX INTEGER (0..10000) MAX-ACCESS read-only STATUS current DESCRIPTION "The transmit output power for LEVEL8 in mW." ::= { dot11PhyTxPowerEntry 9 } dot11CurrentTxPowerLevel OBJECT-TYPE SYNTAX INTEGER (1..8) MAX-ACCESS read-only STATUS current DESCRIPTION "The TxPowerLevel N currently being used to transmit data. Some PHYs also use this value to determine the receiver sensitivity requirements for CCA." ::= { dot11PhyTxPowerEntry 10 } -- ********************************************************************** -- * End of dot11PhyTxPower TABLE -- ********************************************************************** -- ********************************************************************** -- * dot11PhyDSSSEntry TABLE -- ********************************************************************** dot11CurrentChannel OBJECT-TYPE SYNTAX INTEGER (1..14) MAX-ACCESS read-write STATUS current DESCRIPTION "The current operating frequency channel of the DSSS PHY. Valid channel numbers are as defined in 15.4.6.2" ::= { dot11PhyDSSSEntry 1 } dot11DynamicChannelEnabled OBJECT-TYPE SYNTAX TruthValue MAX-ACCESS read-write STATUS current DESCRIPTION "This attribute indicate dynamic channel is enabled." ::= { dot11PhyDSSSEntry 2 } dot11CCAModeSupported OBJECT-TYPE SYNTAX INTEGER (1..7) MAX-ACCESS read-only STATUS current DESCRIPTION "dot11CCAModeSupported is a bit-significant value, representing all of the CCA modes supported by the PHY. Valid values are: energy detect only (ED_ONLY) = 01, carrier sense only (CS_ONLY) = 02, carrier sense and energy detect (ED_and_CS)= 04 or the logical sum of any of these values." ::= { dot11PhyDSSSEntry 3 } dot11CurrentCCAMode OBJECT-TYPE SYNTAX INTEGER {edonly(1), csonly(2), edandcs(4)} MAX-ACCESS read-only STATUS current DESCRIPTION "The current CCA method in operation. Valid values are: energy detect only (edonly) = 01, carrier sense only (csonly) = 02, carrier sense and energy detect (edandcs)= 04." ::= { dot11PhyDSSSEntry 4 } dot11EDThreshold OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-write STATUS current DESCRIPTION "The current Energy Detect Threshold being used by the DSSS PHY." ::= { dot11PhyDSSSEntry 5 } dot11ShortPreambleOptionImplemented OBJECT-TYPE SYNTAX INTEGER {true(1), false(2)} MAX-ACCESS read-only STATUS current DESCRIPTION "This attribute, when true, shall indicate that the short preamble option as deTned in subclause 18.2.2.2 is implemented. The default value of this attribute shall be false." ::= { dot11PhyDSSSEntry 6 } dot11PBCCOptionImplemented OBJECT-TYPE SYNTAX INTEGER {true(1), false(2)} MAX-ACCESS read-only STATUS current DESCRIPTION "This attribute, when true, shall indicate that the PBCC modulation option as defined in subclause 18.4.6.6 is implemented. The default value of this attribute shall be false." ::= { dot11PhyDSSSEntry 7 } -- ********************************************************************** -- * End of dot11PhyDSSSEntry TABLE -- ********************************************************************** -- ********************************************************************** -- * End of 80211 MIB -- ********************************************************************** END